ipmitool/ipmitool-1.8.12f-toolman.patch

2440 lines
66 KiB
Diff
Raw Normal View History

2012-12-04 13:36:20 +00:00
diff -up ./doc/ipmitool.1.manscan ./doc/ipmitool.1
--- ./doc/ipmitool.1.manscan 2012-12-03 15:21:11.757888182 +0100
+++ ./doc/ipmitool.1 2012-12-04 13:13:57.961402879 +0100
@@ -58,30 +58,15 @@ Prompt for the remote server password.
Specify an authentication type to use during IPMIv1.5 \fIlan\fP
session activation. Supported types are NONE, PASSWORD, MD2, MD5, or OEM.
.TP
+\fB\-b\fR <\fIchannel\fP>
+Set destination channel for bridged request.
+.TP
+\fB\-B\fR <\fIchannel\fP>
+Set transit channel for bridged request. (dual bridge)
+.TP
\fB\-c\fR
Present output in CSV (comma separated variable) format.
This is not available with all commands.
-.TP
-\fB\-e\fR <\fIsol_escape_char\fP>
-Use supplied character for SOL session escape character. The default
-is to use \fI~\fP but this can conflict with ssh sessions.
-.TP
-\fB\-K\fR
-Read Kg key from IPMI_KGKEY environment variable.
-.TP
-\fB\-k\fR <\fIkey\fP>
-Use supplied Kg key for IPMIv2 authentication. The default is not to
-use any Kg key.
-.TP
-\fB\-y\fR <\fIhex key\fP>
-Use supplied Kg key for IPMIv2 authentication. The key is expected in
-hexadecimal format and can be used to specify keys with non-printable
-characters. E.g. '-k PASSWORD' and '-y 50415353574F5244' are
-equivalent.
-The default is not to use any Kg key.
-.TP
-\fB\-Y\fR
-Prompt for the Kg key for IPMIv2 authentication.
.TP
\fB\-C\fR <\fIciphersuite\fP>
The remote server authentication, integrity, and encryption algorithms
@@ -89,6 +74,17 @@ to use for IPMIv2 \fIlanplus\fP connecti
IPMIv2 specification. The default is 3 which specifies RAKP\-HMAC\-SHA1
authentication, HMAC\-SHA1\-96 integrity, and AES\-CBC\-128 encryption algorightms.
.TP
+\fB\-d \fIN\fP\fR
+Use device number N to specify the /dev/ipmiN (or
+/dev/ipmi/N or /dev/ipmidev/N) device to use for in-band
+BMC communication. Used to target a specific BMC on a
+multi-node, multi-BMC system through the ipmi device
+driver interface. Default is 0.
+.TP
+\fB\-e\fR <\fIsol_escape_char\fP>
+Use supplied character for SOL session escape character. The default
+is to use \fI~\fP but this can conflict with ssh sessions.
+.TP
\fB\-E\fR
The remote server password is specified by the environment
variable \fIIPMI_PASSWORD\fP.
@@ -98,6 +94,9 @@ Specifies a file containing the remote s
option is absent, or if password_file is empty, the password
will default to NULL.
.TP
+\fB\-g\fR
+Deprecated. Use: -o intelwv2
+.TP
\fB\-h\fR
Get basic usage help from the command line.
.TP
@@ -109,6 +108,16 @@ option is required for \fIlan\fP and \fI
Selects IPMI interface to use. Supported interfaces that are
compiled in are visible in the usage help output.
.TP
+\fB\-k\fR <\fIkey\fP>
+Use supplied Kg key for IPMIv2 authentication. The default is not to
+use any Kg key.
+.TP
+\fB\-K\fR
+Read Kg key from IPMI_KGKEY environment variable.
+.TP
+\fB\-l\fR <\fIlun\fP>
+Set destination lun for raw commands.
+.TP
\fB\-L\fR <\fIprivlvl\fP>
Force session privilege level. Can be CALLBACK, USER,
OPERATOR, ADMINISTRATOR. Default is ADMINISTRATOR.
@@ -117,6 +126,9 @@ OPERATOR, ADMINISTRATOR. Default is ADMI
Set the local IPMB address. The default is 0x20 and there
should be no need to change it for normal operation.
.TP
+\fB\-M\fR <\fIaddress\fP>
+Set transit local address for bridge request. (dual bridge)
+.TP
\fB\-N\fR <\fIsec\fP>
Specify nr. of seconds between retransmissions of lan/lanplus messages.
Default are 2 seconds for lan and 1 second for lanplus interfaces.
@@ -130,7 +142,7 @@ current supported OEM types.
\fB\-O\fR <\fIsel oem\fP>
Open selected file and read OEM SEL event descriptions to be used
during SEL listings. See examples in contrib dir for file format.
-.TP
+.TP
\fB\-p\fR <\fIport\fP>
Remote server UDP port to connect to. Default is 623.
.TP
@@ -143,6 +155,9 @@ option is not recommended.
\fB\-R\fR <\fIcount\fP>
Set the number of retries for lan/lanplus interface (default=4).
.TP
+\fB\-s\fR
+Deprecated. Use: -o supermicro
+.TP
\fB\-S\fR <\fIsdr_cache_file\fP>
Use local file for remote SDR cache. Using a local SDR cache
can drastically increase performance for commands that require
@@ -153,15 +168,11 @@ SDR cache from a remote system can be cr
\fB\-t\fR <\fItarget_address\fP>
Bridge IPMI requests to the remote target address.
.TP
+\fB\-T\fR <\fItransmit_address\fP>
+Set transit address for bridge request. (dual bridge)
+.TP
\fB\-U\fR <\fIusername\fP>
Remote server username, default is NULL user.
-.TP
-\fB\-d \fIN\fP\fR
-Use device number N to specify the /dev/ipmiN (or
-/dev/ipmi/N or /dev/ipmidev/N) device to use for in-band
-BMC communication. Used to target a specific BMC on a
-multi-node, multi-BMC system through the ipmi device
-driver interface. Default is 0.
.TP
\fB\-v\fR
Increase verbose output level. This option may be specified
@@ -171,6 +182,19 @@ outgoing packets.
.TP
\fB\-V\fR
Display version information.
+.TP
+\fB\-y\fR <\fIhex key\fP>
+Use supplied Kg key for IPMIv2 authentication. The key is expected in
+hexadecimal format and can be used to specify keys with non-printable
+characters. E.g. '-k PASSWORD' and '-y 50415353574F5244' are
+equivalent.
+The default is not to use any Kg key.
+.TP
+\fB\-Y\fR
+Prompt for the Kg key for IPMIv2 authentication.
+.TP
+\fB\-z\fR <\fIsize\fP>
+Change Size of Communication Channel. (OEM)
.LP
If no password method is specified then ipmitool will prompt the
@@ -210,172 +234,42 @@ to get option usage help.
ipmitool help
.br
Commands:
- raw Send a RAW IPMI request and print response
- i2c Send an I2C Master Write-Read command and print response
- spd Print SPD info from remote I2C device
- lan Configure LAN Channels
+ bmc Deprecated. Use mc
+ channel Configure Management Controller channels
chassis Get chassis status and set power state
- power Shortcut to chassis power commands
+ dcmi Data Center Management Interface
+ delloem Manage Dell OEM Extensions.
+ echo Used to echo lines to stdout in scripts
+ ekanalyzer run FRU-Ekeying analyzer using FRU files
event Send events to MC
+ exec Run list of commands from file
+ firewall Configure Firmware Firewall
+ fru Print built\-in FRU and scan for FRU locators
+ fwum Update IPMC using Kontron OEM Firmware Update Manager
+ gendev Read/Write Device associated with Generic Device locators sdr
+ hpm Update HPM components using PICMG HPM.1 file
+ i2c Send an I2C Master Write-Read command and print response
+ ime Upgrade/Query Intel ME firmware
+ isol Configure and connect Intel IPMIv1.5 Serial\-over\-LAN
+ kontronoem Manage Kontron OEM Extensions
+ lan Configure LAN Channels
mc Management Controller status and global enables
+ pef Configure Platform Event Filtering (PEF)
+ picmg Run a PICMG/ATA extended command
+ power Shortcut to chassis power commands
+ raw Send a RAW IPMI request and print response
sdr Print Sensor Data Repository entries and readings
- sensor Print detailed sensor information
- fru Print built\-in FRU and scan for FRU locators
sel Print System Event Log (SEL)
- pef Configure Platform Event Filtering (PEF)
+ sensor Print detailed sensor information
+ session Print session information
+ set Set runtime variable for shell and exec
+ shell Launch interactive IPMI shell
sol Configure and connect IPMIv2.0 Serial\-over\-LAN
+ spd Print SPD info from remote I2C device
+ sunoem Manage Sun OEM Extensions
tsol Configure and connect Tyan IPMIv1.5 Serial\-over\-LAN
- isol Configure and connect Intel IPMIv1.5 Serial\-over\-LAN
user Configure Management Controller users
- channel Configure Management Controller channels
- dcmi Data Center Management Interface
- session Print session information
- sunoem Manage Sun OEM Extensions
- kontronoem Manage Kontron OEM Extensions
- picmg Run a PICMG/ATA extended command
- firewall Configure Firmware Firewall
- shell Launch interactive IPMI shell
- exec Run list of commands from file
- set Set runtime variable for shell and exec
- delloem Manage Dell OEM Extensions.
- echo Used to echo lines to stdout in scripts
- ekanalyzer run FRU-Ekeying analyzer using FRU files
- ime Upgrade/Query Intel ME firmware
- hpm Update HPM components using PICMG HPM.1 file
- fwum Update IPMC using Kontron OEM Firmware Update Manager
-
-
-ipmitool chassis help
-.br
-Chassis Commands: status, power, identify, policy, restart_cause, poh, bootdev, bootparam, selftest
-
-ipmitool chassis power help
-.br
-chassis power Commands: status, on, off, cycle, reset, diag, soft
-.TP
-\fIbmc|mc\fP
-.RS
-.TP
-\fIreset\fP <\fBwarm\fR|\fBcold\fR>
-.br
-
-Instructs the BMC to perform a warm or cold reset.
-.TP
-\fIguid\fP
-
-Display the Management Controller Globally Unique IDentifier.
-.TP
-\fIinfo\fP
-.br
-
-Displays information about the BMC hardware, including device
-revision, firmware revision, IPMI version supported, manufacturer ID,
-and information on additional device support.
-.TP
-\fIwatchdog\fP
-.br
-
-These commands allow a user to view and change the current
-state of the watchdog timer.
-.RS
-.TP
-\fIget\fP
-.br
-
-Show current Watchdog Timer settings and countdown state.
-.TP
-\fIreset\fP
-.br
-
-Reset the Watchdog Timer to its most recent state and restart the
-countdown timer.
-.TP
-\fIoff\fP
-.br
-
-Turn off a currently running Watchdog countdown timer.
-.RE
-.TP
-\fIselftest\fP
-.br
-
-Check on the basic health of the BMC by executing the Get Self Test
-results command and report the results.
-.TP
-\fIgetenables\fP
-.br
-
-Displays a list of the currently enabled options for the BMC.
-.br
-.TP
-\fIsetenables\fP <\fBoption\fR>=[\fIon\fP|\fIoff\fP]
-.br
-
-Enables or disables the given \fIoption\fR. This command is
-only supported over the system interface according to the IPMI
-specification. Currently supported values for \fIoption\fR include:
-.RS
-.TP
-\fIrecv_msg_intr\fP
-.br
-
-Receive Message Queue Interrupt
-.TP
-\fIevent_msg_intr\fP
-.br
-
-Event Message Buffer Full Interrupt
-.TP
-\fIevent_msg\fP
-.br
-
-Event Message Buffer
-.TP
-\fIsystem_event_log\fP
-.br
-
-System Event Logging
-.TP
-\fIoem0\fP
-.br
-
-OEM\-Defined option #0
-.TP
-\fIoem1\fP
-.br
-
-OEM\-Defined option #1
-.TP
-\fIoem2\fP
-.br
-OEM\-Defined option #2
-
-.RE
-.TP
-\fIgetsysinfo\fP <\fBargument\fP>
-Retrieves system info from bmc for given argument.
-.br
-See \fIsetsysinfo\fP for argument definitions
-.TP
-\fIsetsysinfo\fP <\fBargument\fP> <\fBstring\fP>
-Stores system info string to bmc for given argument
-.RS
-.TP
-Possible arguments are:
-.RS
-.TP
-\fIprimary_os_name\fP Primary Operating System Name
-.TP
-\fIos_name\fP Operating System Name
-.TP
-\fIsystem_name\fP System Name of Server
-.TP
-\fIdelloem_os_version\fP Running versin of operating system
-.TP
-\fIdelloem_URL\fP URL of BMC Webserver
-.RE
-.RE
.TP
\fIchannel\fP
.RS
@@ -397,6 +291,8 @@ Possible privilege levels are:
\fI4\fP Administrator level
.br
\fI5\fP OEM Proprietary level
+.br
+\fI15\fP No access
.RE
.TP
\fIinfo\fP [\fBchannel number\fR]
@@ -421,7 +317,7 @@ Channel 0xf info:
.RE
.TP
\fIgetaccess\fP <\fBchannel number\fR> [<\fBuserid\fR>]
-.br
+.RS
Configure the given userid as the default on the given channel number.
When the given channel is subsequently used, the user is identified
@@ -439,242 +335,192 @@ Configure user access information on the
Displays the list of cipher suites supported for the given
application (ipmi or sol) on the given channel.
.RE
+.RE
.TP
\fIchassis\fP
.RS
.TP
\fIstatus\fP
-.br
-Displays information regarding the high\-level
-status of the system chassis and main power
-subsystem.
+Status information related to power, buttons, cooling, drives and faults.
+.RS
+.RE
.TP
-\fIpoh\fP
-.br
-
-This command will return the Power\-On Hours counter.
-.TP
-\fIidentify\fP <\fBinterval\fR>
-
-Control the front panel identify light. Default interval
-is 15 seconds. Use 0 to turn off. Use "force" to turn on
-indefinitely.
+\fIpower\fP
+.RS
.TP
-\fIrestart_cause\fP
-.br
-
-Query the chassis for the cause of the last system restart.
+\fIstatus\fP
+.RS
+.RE
+.TP
+\fIon\fP
+.RS
+.RE
+.TP
+\fIoff\fP
+.RS
+.RE
+.TP
+\fIcycle\fP
+.RS
+.RE
+.TP
+\fIreset\fP
+.RS
+.RE
+.TP
+\fIdiag\fP
+.RS
+.RE
+.TP
+\fIsoft\fP
+.RS
+.RE
+.RE
.TP
-\fIselftest\fP
-.br
+\fIidentify\fP [<seconds>|force]
-Check on the basic health of the BMC by executing the Get Self Test
-results command and report the results.
+Identify interval.
+.br
+Default is 15 seconds.
+.br
+0 - Off
+.br
+force - To turn on indefinitely
+.RS
+.RE
.TP
\fIpolicy\fP
-.br
-Set the chassis power policy in the event power failure.
+What to do when power is restored.
.RS
.TP
\fIlist\fP
-.br
-Return supported policies.
+Show available options.
+.RS
+.RE
.TP
-\fIalways\-on\fP
-.br
-
-Turn on when power is restored.
+\fIalways-on\fP
+.RS
+.RE
.TP
\fIprevious\fP
-.br
-
-Returned to previous state when power is restored.
-.TP
-\fIalways\-off\fP
-.br
-
-Stay off after power is restored.
+.RS
.RE
.TP
-\fIpower\fP
-.br
-
-Performs a chassis control command to view and
-change the power state.
+\fIalways-off\fP
.RS
-.TP
-\fIstatus\fP
-.br
-
-Show current chassis power status.
-.TP
-\fIon\fP
-.br
-
-Power up chassis.
-.TP
-\fIoff\fP
-.br
-
-Power down chassis into soft off (S4/S5 state).
-\fBWARNING\fR: This command does not initiate a clean
-shutdown of the operating system prior to powering down the system.
-.TP
-\fIcycle\fP
-.br
-
-Provides a power off interval of at least 1 second. No action
-should occur if chassis power is in S4/S5 state, but it is
-recommended to check power state first and only issue a power
-cycle command if the system power is on or in lower sleep
-state than S4/S5.
-.TP
-\fIreset\fP
-.br
-
-This command will perform a hard reset.
-.TP
-\fIdiag\fP
-.br
+.RE
+.RE
-Pulse a diagnostic interrupt (NMI) directly to the processor(s).
.TP
-\fIsoft\fP
-.br
+\fIrestart_cause\fP
-Initiate a soft\-shutdown of OS via ACPI. This can be done in a
-number of ways, commonly by simulating an overtemperture or by
-simulating a power button press. It is necessary for there to
-be Operating System support for ACPI and some sort of daemon
-watching for events for this soft power to work.
+Last restart cause.
+.RS
.RE
.TP
-\fIbootdev\fP <\fBdevice\fR> [<\fIclear\-cmos\fP=\fByes\fR|\fBno\fR>] [<\fIoptions\fP=\fBhelp,...\fR>]
-.br
-
-Request the system to boot from an alternate boot device on next reboot.
-The \fIclear\-cmos\fP option, if supplied, will instruct the BIOS to
-clear its CMOS on the next reboot. Various options may be used to modify
-the boot device settings. Run \fI"bootdev none options=help"\fP for a list of
-available boot device modifiers/options.
+\fIpoh\fP
+Get power on hours.
.RS
+.RE
.TP
-Currently supported values for <device> are:
+\fIbootdev\fP
+.RS
.TP
\fInone\fP
-.br
-Do not change boot device
+Do not change boot device order.
+.RS
+.RE
.TP
\fIpxe\fP
-.br
-Force PXE boot
+Force PXE boot.
+.RS
+.RE
.TP
\fIdisk\fP
-.br
-Force boot from BIOS default boot device
+Force boot from default Hard-drive.
+.RS
+.RE
.TP
\fIsafe\fP
-.br
-Force boot from BIOS default boot device, request Safe Mode
+Force boot from default Hard-drive, request Safe Mode.
+.RS
+.RE
.TP
\fIdiag\fP
-.br
-Force boot from diagnostic partition
+Force boot from Diagnostic Partition.
+.RS
+.RE
.TP
\fIcdrom\fP
-.br
-Force boot from CD/DVD
+Force boot from CD/DVD.
+.RS
+.RE
.TP
\fIbios\fP
-.br
-Force boot into BIOS setup
+Force boot into BIOS Setup.
+.RS
+.RE
.TP
\fIfloppy\fP
-.br
-Force boot from Floppy/primary removable media
+Force boot from Floppy/primary removable media.
+.RS
+.RE
.RE
.TP
\fIbootparam\fP
-.br
-
-Get or set various system boot option parameters.
-.RS
-.TP
-\fIget\fP <\fBparam #\fR>
-.br
-
-Get boot parameter. Currently supported values for <\fBparam #\fR> are:
-
-\fI0\fP - Set In Progress
-
-\fI1\fP - Service Partition Selector
-
-\fI2\fP - Service Partition Scan
-
-\fI3\fP - BMC Boot Flag Valid Bit Clearing
-
-\fI4\fP - Boot Info Acknowledge
-
-\fI5\fP - Boot Flags
-
-\fI6\fP - Boot Initiator Info
-
-\fI7\fP - Boot Initiator Mailbox
-.br
-
-.TP
-\fIset\fP <\fBoption\fR> [\fBvalue ...\fR]
-.br
-
-Set boot parameter.
-
.RS
.TP
-Currently supported values for \fB<option>\fR are:
-.TP
\fIforce_pxe\fP
-.br
Force PXE boot
+.RS
+.RE
.TP
\fIforce_disk\fP
-.br
-Force boot from default hard-drive
+Force boot from default Hard-drive
+.RS
+.RE
.TP
\fIforce_safe\fP
-.br
-Force boot from default hard-drive, request Safe Mode
+Force boot from default Hard-drive, request Safe Mode
+.RS
+.RE
.TP
\fIforce_diag\fP
-.br
-Force boot from diagnostic partition
+Force boot from Diagnostic Partition
+.RS
+.RE
.TP
\fIforce_cdrom\fP
-.br
-Force boot from CD/DVD
+Force boot from CD/DVD
+.RS
+.RE
.TP
\fIforce_bios\fP
-.br
-
-Force boot into BIOS setup
+Force boot into BIOS Setup
+.RS
+.RE
.RE
+.TP
+\fIselftest\fP
+.RS
.RE
.RE
.TP
@@ -854,242 +700,23 @@ Ping/Pong Message for DCMI Discovery.
.RE
.RE
.TP
-\fIekanalyzer\fP <\fBcommand\fR> <\fBxx=filename1\fR> <\fBxx=filename2\fR> [<\fBrc=filename3\fR>] \fB...\fR
+\fIdelloem\fP
.RS
-.TP
.br
-\fINOTE\fP : This command can support a maximum of 8 files per command line
-.TP
-.br
-\fIfilename1\fP : binary file that stores FRU data of a Carrier or an AMC module
+
+The delloem commands provide information on Dell-specific features.
.TP
+\fIsetled {b:d.f} {state..}\fP
+.RS
.br
-\fIfilename2\fP : binary file that stores FRU data of an AMC module.
- These binary files can be generated from command:
- \fIipmitool fru read <id> <filename>\fP
-.TP
+
+Sets the drive backplane LEDs for a device.
.br
-\fIfilename3\fP : configuration file used for configuring On-Carrier Device ID
-or OEM GUID. This file is optional.
-.TP
+{b:d.f} = PCI Address of device (eg. 06:00.0)
.br
-\fIxx\fP : indicates the type of the file. It can take the following value:
+{state} = one or more of the following:
.RS
-.TP
-.br
-\fIoc\fP : On-Carrier device
-.TP
-.br
-\fIa1\fP : AMC slot A1
-.TP
-.br
-\fIa2\fP : AMC slot A2
-.TP
-.br
-\fIa3\fP : AMC slot A3
-.TP
-.br
-\fIa4\fP : AMC slot A4
-.TP
-.br
-\fIb1\fP : AMC slot B1
-.TP
-.br
-\fIb2\fP : AMC slot B2
-.TP
-.br
-\fIb3\fP : AMC slot B3
-.TP
-.br
-\fIb4\fP : AMC slot B4
-.TP
-.br
-\fIsm\fP : Shelf Manager
-
-.RE
-.TP
-.br
-The available commands for ekanalyzer are:
-
-.RE
-.RS
-.TP
-\fIprint\fP [<\fBcarrier\fR | \fBpower\fR | \fBall\fR>]
-.RS
-.TP
-\fIcarrier\fP (default) <\fBoc=filename1\fR> <\fBoc=filename2\fR> \fB...\fR
-.br
-
-Display point to point physical connectivity between carriers and AMC modules.
- Example:
- > ipmitool ekanalyzer print carrier oc=fru oc=carrierfru
- From Carrier file: fru
- Number of AMC bays supported by Carrier: 2
- AMC slot B1 topology:
- Port 0 =====> On Carrier Device ID 0, Port 16
- Port 1 =====> On Carrier Device ID 0, Port 12
- Port 2 =====> AMC slot B2, Port 2
- AMC slot B2 topology:
- Port 0 =====> On Carrier Device ID 0, Port 3
- Port 2 =====> AMC slot B1, Port 2
- *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
- From Carrier file: carrierfru
- On Carrier Device ID 0 topology:
- Port 0 =====> AMC slot B1, Port 4
- Port 1 =====> AMC slot B1, Port 5
- Port 2 =====> AMC slot B2, Port 6
- Port 3 =====> AMC slot B2, Port 7
- AMC slot B1 topology:
- Port 0 =====> AMC slot B2, Port 0
- AMC slot B1 topology:
- Port 1 =====> AMC slot B2, Port 1
- Number of AMC bays supported by Carrier: 2
-
-.TP
-\fIpower\fP <\fBxx=filename1\fR> <\fBxx=filename2\fR> \fB...\fr
-.br
-
-Display power supply informations between carrier and AMC modules.
-.TP
-\fIall\fP <\fBxx=filename\fR> <\fBxx=filename\fR> \fB...\fr
-.br
-
-Display both physical connectivity and power supply of each carrier and AMC
-modules.
-
-.RE
-.TP
-\fIfrushow\fP <\fBxx=filename\fR>
-.br
-Convert a binary FRU file into human readable text format. Use -v option to get
-more display information.
-
-.RE
-.RS
-.TP
-\fIsummary\fP [<\fBmatch\fR | \fBunmatch\fR | \fBall\fR>]
-.RS
-.TP
-\fImatch\fP (default) <\fBxx=filename\fR> <\fBxx=filename\fR> \fB...\fR
-.br
-Display only matched results of Ekeying match between an On-Carrier device
-and an AMC module or between 2 AMC modules. Example:
- > ipmitool ekanalyzer summary match oc=fru b1=amcB1 a2=amcA2
- On-Carrier Device vs AMC slot B1
- AMC slot B1 port 0 ==> On-Carrier Device 0 port 16
- Matching Result
- - From On-Carrier Device ID 0
- -Channel ID 11 || Lane 0: enable
- -Link Type: AMC.2 Ethernet
- -Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
- -Link Group ID: 0 || Link Asym. Match: exact match
- - To AMC slot B1
- -Channel ID 0 || Lane 0: enable
- -Link Type: AMC.2 Ethernet
- -Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
- -Link Group ID: 0 || Link Asym. Match: exact match
- *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
- AMC slot B1 port 1 ==> On-Carrier Device 0 port 12
- Matching Result
- - From On-Carrier Device ID 0
- -Channel ID 6 || Lane 0: enable
- -Link Type: AMC.2 Ethernet
- -Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
- -Link Group ID: 0 || Link Asym. Match: exact match
- - To AMC slot B1
- -Channel ID 1 || Lane 0: enable
- -Link Type: AMC.2 Ethernet
- -Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
- -Link Group ID: 0 || Link Asym. Match: exact match
- *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
- On-Carrier Device vs AMC slot A2
- AMC slot A2 port 0 ==> On-Carrier Device 0 port 3
- Matching Result
- - From On-Carrier Device ID 0
- -Channel ID 9 || Lane 0: enable
- -Link Type: AMC.2 Ethernet
- -Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
- -Link Group ID: 0 || Link Asym. Match: exact match
- - To AMC slot A2
- -Channel ID 0 || Lane 0: enable
- -Link Type: AMC.2 Ethernet
- -Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
- -Link Group ID: 0 || Link Asym. Match: exact match
- *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
- AMC slot B1 vs AMC slot A2
- AMC slot A2 port 2 ==> AMC slot B1 port 2
- Matching Result
- - From AMC slot B1
- -Channel ID 2 || Lane 0: enable
- -Link Type: AMC.3 Storage
- -Link Type extension: Serial Attached SCSI (SAS/SATA)
- -Link Group ID: 0 || Link Asym. Match: FC or SAS interface {exact match}
- - To AMC slot A2
- -Channel ID 2 || Lane 0: enable
- -Link Type: AMC.3 Storage
- -Link Type extension: Serial Attached SCSI (SAS/SATA)
- -Link Group ID: 0 || Link Asym. Match: FC or SAS interface {exact match}
- *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
-.TP
-\fIunmatch\fP <\fBxx=filename\fR> <\fBxx=filename\fR> \fB...\fr
-.br
-
-Display the unmatched results of Ekeying match between an On-Carrier device
-and an AMC module or between 2 AMC modules
-.TP
-\fIall\fP <\fBxx=filename\fR> <\fBxx=filename\fR> \fB...\fr
-.br
-
-Display both matched result and unmatched results of Ekeying match between two
-cards or two modules.
-.RE
-.RE
-.TP
-\fIime\fP
-.RS
-.TP
-\fIhelp\fP
-.br
-
-Print usage information
-.TP
-\fIinfo\fP
-
-Displays information about the Manageability Engine (ME)
-.TP
-\fIupdate\fP <\fBfile\fR>
-.br
-
-Upgrade the ME firmware with the specified image file
-.br
-\fBWARNING\fR You MUST use a supported image provided by your board vendor
-.br
-.TP
-\fIrollback\fP
-
-Perform manual rollback of the ME firmware
-
-.RE
-.RE
-
-.TP
-\fIdelloem\fP
-.RS
-.br
-
-The delloem commands provide information on Dell-specific features.
-.TP
-\fIsetled {b:d.f} {state..}\fP
-.RS
-.br
-
-Sets the drive backplane LEDs for a device.
-.br
-{b:d.f} = PCI Address of device (eg. 06:00.0)
-.br
-{state} = one or more of the following:
-.RS
-\fIonline | present | hotspare | identify | rebuilding | fault | predict | critical | failed\fP
+\fIonline | present | hotspare | identify | rebuilding | fault | predict | critical | failed\fP
.br
.RE
.RE
@@ -1277,45 +904,224 @@ Disables set power cap.
.RE
.RS
-.br
.TP
-\fIwindbg\fP
-.RS
-.br
-\fIwindbg start\fP
-.RS
-.br
-Starts the windbg session (Cold Reset & SOL Activation)
-.RE
-\fIwindbg end\fP
+\fIvFlash info Card\fP
.RS
.br
-Ends the windbg session (SOL Deactivation)
+Shows Extended SD Card information.
+.RE
.RE
+.TP
+\fIecho\fP
+
+For echoing lines to stdout in scripts.
+.RS
.RE
.TP
-\fIvFlash info Card\fP
+\fIekanalyzer\fP <\fBcommand\fR> <\fBxx=filename1\fR> <\fBxx=filename2\fR> [<\fBrc=filename3\fR>] \fB...\fR
.RS
+.TP
.br
-
-Shows Extended SD Card information
-.RE
-.RE
+\fINOTE\fP : This command can support a maximum of 8 files per command line
.TP
-.TP
-\fIevent\fP
+.br
+\fIfilename1\fP : binary file that stores FRU data of a Carrier or an AMC module
+.TP
+.br
+\fIfilename2\fP : binary file that stores FRU data of an AMC module.
+ These binary files can be generated from command:
+ \fIipmitool fru read <id> <filename>\fP
+.TP
+.br
+\fIfilename3\fP : configuration file used for configuring On-Carrier Device ID
+or OEM GUID. This file is optional.
+.TP
+.br
+\fIxx\fP : indicates the type of the file. It can take the following value:
.RS
-.TP
-<\fBpredefined event number\fR \fIN\fR>
-.br
-
-Send a pre\-defined test event to the System Event Log. The following
-events are included as a means to test the functionality of the
-System Event Log component of the BMC (an entry will be added each
-time the event \fIN\fP command is executed).
-
-Currently supported values for \fIN\fR are:
+.TP
+.br
+\fIoc\fP : On-Carrier device
+.TP
+.br
+\fIa1\fP : AMC slot A1
+.TP
+.br
+\fIa2\fP : AMC slot A2
+.TP
+.br
+\fIa3\fP : AMC slot A3
+.TP
+.br
+\fIa4\fP : AMC slot A4
+.TP
+.br
+\fIb1\fP : AMC slot B1
+.TP
+.br
+\fIb2\fP : AMC slot B2
+.TP
+.br
+\fIb3\fP : AMC slot B3
+.TP
+.br
+\fIb4\fP : AMC slot B4
+.TP
+.br
+\fIsm\fP : Shelf Manager
+
+.RE
+.TP
+.br
+The available commands for ekanalyzer are:
+
+.RE
+.RS
+.TP
+\fIprint\fP [<\fBcarrier\fR | \fBpower\fR | \fBall\fR>]
+.RS
+.TP
+\fIcarrier\fP (default) <\fBoc=filename1\fR> <\fBoc=filename2\fR> \fB...\fR
+.br
+
+Display point to point physical connectivity between carriers and AMC modules.
+ Example:
+ > ipmitool ekanalyzer print carrier oc=fru oc=carrierfru
+ From Carrier file: fru
+ Number of AMC bays supported by Carrier: 2
+ AMC slot B1 topology:
+ Port 0 =====> On Carrier Device ID 0, Port 16
+ Port 1 =====> On Carrier Device ID 0, Port 12
+ Port 2 =====> AMC slot B2, Port 2
+ AMC slot B2 topology:
+ Port 0 =====> On Carrier Device ID 0, Port 3
+ Port 2 =====> AMC slot B1, Port 2
+ *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
+ From Carrier file: carrierfru
+ On Carrier Device ID 0 topology:
+ Port 0 =====> AMC slot B1, Port 4
+ Port 1 =====> AMC slot B1, Port 5
+ Port 2 =====> AMC slot B2, Port 6
+ Port 3 =====> AMC slot B2, Port 7
+ AMC slot B1 topology:
+ Port 0 =====> AMC slot B2, Port 0
+ AMC slot B1 topology:
+ Port 1 =====> AMC slot B2, Port 1
+ Number of AMC bays supported by Carrier: 2
+
+.TP
+\fIpower\fP <\fBxx=filename1\fR> <\fBxx=filename2\fR> \fB...\fr
+.br
+
+Display power supply informations between carrier and AMC modules.
+.TP
+\fIall\fP <\fBxx=filename\fR> <\fBxx=filename\fR> \fB...\fr
+.br
+
+Display both physical connectivity and power supply of each carrier and AMC
+modules.
+
+.RE
+.TP
+\fIfrushow\fP <\fBxx=filename\fR>
+.br
+Convert a binary FRU file into human readable text format. Use -v option to get
+more display information.
+
+.RE
+.RS
+.TP
+\fIsummary\fP [<\fBmatch\fR | \fBunmatch\fR | \fBall\fR>]
+.RS
+.TP
+\fImatch\fP (default) <\fBxx=filename\fR> <\fBxx=filename\fR> \fB...\fR
+.br
+Display only matched results of Ekeying match between an On-Carrier device
+and an AMC module or between 2 AMC modules. Example:
+ > ipmitool ekanalyzer summary match oc=fru b1=amcB1 a2=amcA2
+ On-Carrier Device vs AMC slot B1
+ AMC slot B1 port 0 ==> On-Carrier Device 0 port 16
+ Matching Result
+ - From On-Carrier Device ID 0
+ -Channel ID 11 || Lane 0: enable
+ -Link Type: AMC.2 Ethernet
+ -Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
+ -Link Group ID: 0 || Link Asym. Match: exact match
+ - To AMC slot B1
+ -Channel ID 0 || Lane 0: enable
+ -Link Type: AMC.2 Ethernet
+ -Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
+ -Link Group ID: 0 || Link Asym. Match: exact match
+ *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
+ AMC slot B1 port 1 ==> On-Carrier Device 0 port 12
+ Matching Result
+ - From On-Carrier Device ID 0
+ -Channel ID 6 || Lane 0: enable
+ -Link Type: AMC.2 Ethernet
+ -Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
+ -Link Group ID: 0 || Link Asym. Match: exact match
+ - To AMC slot B1
+ -Channel ID 1 || Lane 0: enable
+ -Link Type: AMC.2 Ethernet
+ -Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
+ -Link Group ID: 0 || Link Asym. Match: exact match
+ *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
+ On-Carrier Device vs AMC slot A2
+ AMC slot A2 port 0 ==> On-Carrier Device 0 port 3
+ Matching Result
+ - From On-Carrier Device ID 0
+ -Channel ID 9 || Lane 0: enable
+ -Link Type: AMC.2 Ethernet
+ -Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
+ -Link Group ID: 0 || Link Asym. Match: exact match
+ - To AMC slot A2
+ -Channel ID 0 || Lane 0: enable
+ -Link Type: AMC.2 Ethernet
+ -Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
+ -Link Group ID: 0 || Link Asym. Match: exact match
+ *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
+ AMC slot B1 vs AMC slot A2
+ AMC slot A2 port 2 ==> AMC slot B1 port 2
+ Matching Result
+ - From AMC slot B1
+ -Channel ID 2 || Lane 0: enable
+ -Link Type: AMC.3 Storage
+ -Link Type extension: Serial Attached SCSI (SAS/SATA)
+ -Link Group ID: 0 || Link Asym. Match: FC or SAS interface {exact match}
+ - To AMC slot A2
+ -Channel ID 2 || Lane 0: enable
+ -Link Type: AMC.3 Storage
+ -Link Type extension: Serial Attached SCSI (SAS/SATA)
+ -Link Group ID: 0 || Link Asym. Match: FC or SAS interface {exact match}
+ *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
+.TP
+\fIunmatch\fP <\fBxx=filename\fR> <\fBxx=filename\fR> \fB...\fr
+.br
+
+Display the unmatched results of Ekeying match between an On-Carrier device
+and an AMC module or between 2 AMC modules
+.TP
+\fIall\fP <\fBxx=filename\fR> <\fBxx=filename\fR> \fB...\fr
+.br
+
+Display both matched result and unmatched results of Ekeying match between two
+cards or two modules.
+.RE
+.RE
+.TP
+\fIevent\fP
+.RS
+.TP
+<\fBpredefined event number\fR \fIN\fR>
+.br
+
+Send a pre\-defined test event to the System Event Log. The following
+events are included as a means to test the functionality of the
+System Event Log component of the BMC (an entry will be added each
+time the event \fIN\fP command is executed).
+
+Currently supported values for \fIN\fR are:
.br
\fI1\fP Temperature: Upper Critical: Going High
.br
@@ -1445,52 +1251,135 @@ sdr list # get a list of sdr records
sel list # get a list of sel records
.RE
.TP
-\fIfru\fP
+\fIfirewall\fP
+.br
+
+This command supports the Firmware Firewall capability. It may be used to
+add or remove security-based restrictions on certain commands/command
+sub-functions or to list the current firmware firewall restrictions set on
+any commands. For each firmware firewall command listed below, parameters
+may be included to cause the command to be executed with increasing
+granularity on a specific LUN, for a specific NetFn, for a specific IPMI
+Command, and finally for a specific command's sub-function (see Appendix H in the
+IPMI 2.0 Specification for a listing of any sub-function numbers that may
+be associated with a particular command).
+
+Parameter syntax and dependencies are as follows:
+
+[<\fIchannel\fP \fBH\fR>] [<\fIlun\fP \fBL\fR> [ <\fInetfn\fP \fBN\fR> [<\fIcommand\fP \fBC\fR [<\fIsubfn\fP \fBS\fR>]]]]
+
+Note that if "netfn <\fBN\fR>" is specified, then "lun <\fBL\fR>" must also be
+specified; if "command <\fBC\fR>" is specified, then "netfn <\fBN\fR>" (and
+therefore "lun <\fBL\fR>") must also be specified, and so forth.
+
+"channel <\fBH\fR>" is an optional and standalone parameter. If not specified,
+the requested operation will be performed on the current channel. Note that
+command support may vary from channel to channel.
+
+Firmware firewall commands:
.RS
.TP
-\fIprint\fP
+\fIinfo\fP [<\fBParms as described above\fR>]
.br
-Read all Field Replaceable Unit (FRU) inventory data and extract
-such information as serial number, part number, asset tags, and
-short strings describing the chassis, board, or product.
+List firmware firewall information for the specified LUN, NetFn, and
+Command (if supplied) on the current or specified channel. Listed
+information includes the support, configurable, and enabled bits for
+the specified command or commands.
+
+Some usage examples:
+.RS
.TP
-\fIread\fP <\fBfru id\fR> <\fBfru file\fR>
+\fIinfo\fP [<\fBchannel H\fR>] [<\fBlun L\fR>]
.br
-\fBfru id\fR is the digit ID of the FRU (see output of 'fru print').
-\fBfru file\fR is the absolute pathname of a file in which to dump the
-binary FRU data pertaining to the specified FRU entity.
+This command will list firmware firewall information for all NetFns for the
+specified LUN on either the current or the specified channel.
.TP
-\fIwrite\fP <\fBfru id\fR> <\fBfru file\fR>
+\fIinfo\fP [<\fBchannel H\fR>] [<\fBlun L\fR> [ <\fBnetfn N\fR> ]
.br
-\fBfru id\fR is the digit ID of the FRU (see output of 'fru print').
-\fBfru file\fR is the absolute pathname of a file from which to pull
-the binary FRU data before uploading it to the specified FRU.
+This command will print out all command information for a single LUN/NetFn pair.
.TP
-\fIupgEkey\fP <\fBfru id\fR> <\fBfru file\fR>
+\fIinfo\fP [<\fBchannel H\fR>] [<\fBlun L\fR> [ <\fBnetfn N\fR> [<\fBcommand C\fR] ]]
.br
-Update a multirecord FRU location.
-\fBfru id\fR is the digit ID of the FRU (see output of 'fru print').
-\fBfru file\fR is the absolute pathname of a file from which to pull the
-binary FRU data to upload into the specified multirecord FRU entity.
-
+This prints out detailed, human-readable information showing the support, configurable,
+and enabled bits for the specified command on the specified LUN/NetFn pair. Information
+will be printed about each of the command subfunctions.
.TP
-\fIedit\fP <\fBfru id\fR>
+\fIinfo\fP [<\fBchannel H\fR>] [<\fBlun L\fR> [ <\fBnetfn N\fR> [<\fBcommand C\fR [<\fBsubfn S\fR>]]]]
.br
-This command provides interactive editing of some supported records, namely
-PICMG Carrier Activation Record. \fBfru id\fR is the digit ID of the FRU
-(see output of 'fru print'); default is 0.
-
+Print out information for a specific sub-function.
+.RE
.TP
-\fIedit\fP <\fBfru id\fR> \fBfield\fR <\fBsection\fR> <\fBindex\fR> <\fBstring\fR>
+\fIenable\fP [<\fBParms as described above\fR>]
.br
-This command may be used to set a field string to a new value. It replaces
-the FRU data found at \fBindex\fR in the specified \fBsection\fR with the
+This command is used to enable commands for a given NetFn/LUN combination on
+the specified channel.
+.TP
+\fIdisable\fP [<\fBParms as described above\fR>] [\fBforce\fR]
+.br
+
+This command is used to disable commands for a given NetFn/LUN combination on
+the specified channel. Great care should be taken if using the "force"
+option so as not to disable the "Set Command Enables" command.
+.TP
+\fIreset\fP [<\fBParms as described above\fR>]
+.br
+
+This command may be used to reset the firmware firewall back to a state
+where all commands and command sub-functions are enabled.
+.RE
+.TP
+\fIfru\fP
+.RS
+.TP
+\fIprint\fP
+.br
+
+Read all Field Replaceable Unit (FRU) inventory data and extract
+such information as serial number, part number, asset tags, and
+short strings describing the chassis, board, or product.
+.TP
+\fIread\fP <\fBfru id\fR> <\fBfru file\fR>
+.br
+
+\fBfru id\fR is the digit ID of the FRU (see output of 'fru print').
+\fBfru file\fR is the absolute pathname of a file in which to dump the
+binary FRU data pertaining to the specified FRU entity.
+.TP
+\fIwrite\fP <\fBfru id\fR> <\fBfru file\fR>
+.br
+
+\fBfru id\fR is the digit ID of the FRU (see output of 'fru print').
+\fBfru file\fR is the absolute pathname of a file from which to pull
+the binary FRU data before uploading it to the specified FRU.
+.TP
+\fIupgEkey\fP <\fBfru id\fR> <\fBfru file\fR>
+.br
+
+Update a multirecord FRU location.
+\fBfru id\fR is the digit ID of the FRU (see output of 'fru print').
+\fBfru file\fR is the absolute pathname of a file from which to pull the
+binary FRU data to upload into the specified multirecord FRU entity.
+
+.TP
+\fIedit\fP <\fBfru id\fR>
+.br
+
+This command provides interactive editing of some supported records, namely
+PICMG Carrier Activation Record. \fBfru id\fR is the digit ID of the FRU
+(see output of 'fru print'); default is 0.
+
+.TP
+\fIedit\fP <\fBfru id\fR> \fBfield\fR <\fBsection\fR> <\fBindex\fR> <\fBstring\fR>
+.br
+
+This command may be used to set a field string to a new value. It replaces
+the FRU data found at \fBindex\fR in the specified \fBsection\fR with the
supplied \fBstring\fR.
.RS
@@ -1530,91 +1419,6 @@ Storage Areas and may be refer to:
This command edits the data found in the multirecord area. Support for
OEM specific records is limited.
.RE
-.TP
-\fIfirewall\fP
-.br
-
-This command supports the Firmware Firewall capability. It may be used to
-add or remove security-based restrictions on certain commands/command
-sub-functions or to list the current firmware firewall restrictions set on
-any commands. For each firmware firewall command listed below, parameters
-may be included to cause the command to be executed with increasing
-granularity on a specific LUN, for a specific NetFn, for a specific IPMI
-Command, and finally for a specific command's sub-function (see Appendix H in the
-IPMI 2.0 Specification for a listing of any sub-function numbers that may
-be associated with a particular command).
-
-Parameter syntax and dependencies are as follows:
-
-[<\fIchannel\fP \fBH\fR>] [<\fIlun\fP \fBL\fR> [ <\fInetfn\fP \fBN\fR> [<\fIcommand\fP \fBC\fR [<\fIsubfn\fP \fBS\fR>]]]]
-
-Note that if "netfn <\fBN\fR>" is specified, then "lun <\fBL\fR>" must also be
-specified; if "command <\fBC\fR>" is specified, then "netfn <\fBN\fR>" (and
-therefore "lun <\fBL\fR>") must also be specified, and so forth.
-
-"channel <\fBH\fR>" is an optional and standalone parameter. If not specified,
-the requested operation will be performed on the current channel. Note that
-command support may vary from channel to channel.
-
-Firmware firewall commands:
-.RS
-.TP
-\fIinfo\fP [<\fBParms as described above\fR>]
-.br
-
-List firmware firewall information for the specified LUN, NetFn, and
-Command (if supplied) on the current or specified channel. Listed
-information includes the support, configurable, and enabled bits for
-the specified command or commands.
-
-Some usage examples:
-.RS
-.TP
-\fIinfo\fP [<\fBchannel H\fR>] [<\fBlun L\fR>]
-.br
-
-This command will list firmware firewall information for all NetFns for the
-specified LUN on either the current or the specified channel.
-.TP
-\fIinfo\fP [<\fBchannel H\fR>] [<\fBlun L\fR> [ <\fBnetfn N\fR> ]
-.br
-
-This command will print out all command information for a single LUN/NetFn pair.
-.TP
-\fIinfo\fP [<\fBchannel H\fR>] [<\fBlun L\fR> [ <\fBnetfn N\fR> [<\fBcommand C\fR] ]]
-.br
-
-This prints out detailed, human-readable information showing the support, configurable,
-and enabled bits for the specified command on the specified LUN/NetFn pair. Information
-will be printed about each of the command subfunctions.
-.TP
-\fIinfo\fP [<\fBchannel H\fR>] [<\fBlun L\fR> [ <\fBnetfn N\fR> [<\fBcommand C\fR [<\fBsubfn S\fR>]]]]
-.br
-
-Print out information for a specific sub-function.
-.RE
-.TP
-\fIenable\fP [<\fBParms as described above\fR>]
-.br
-
-This command is used to enable commands for a given NetFn/LUN combination on
-the specified channel.
-.TP
-\fIdisable\fP [<\fBParms as described above\fR>] [\fBforce\fR]
-.br
-
-This command is used to disable commands for a given NetFn/LUN combination on
-the specified channel. Great care should be taken if using the "force"
-option so as not to disable the "Set Command Enables" command.
-.TP
-\fIreset\fP [<\fBParms as described above\fR>]
-.br
-
-This command may be used to reset the firmware firewall back to a state
-where all commands and command sub-functions are enabled.
-
-.RE
-
.TP
\fIfwum\fP
.RS
@@ -1655,7 +1459,28 @@ Ask IPMC to rollback to previous version
Show firmware upgrade log.
.RE
+.TP
+\fIgendev\fP
+.RS
+.TP
+\fIlist\fP
+
+List All Generic Device Locators.
+.RS
+.RE
+.TP
+\fIread\fP <\fBsdr name\fR> <\fBfile\fR>
+
+Read to file eeprom specify by Generic Device Locators.
+.RS
+.RE
+.TP
+\fIwrite\fP <\fBsdr name\fR> <\fBfile\fR>
+Write from file eeprom specify by Generic Device Locators
+.RS
+.RE
+.RE
.TP
\fIhpm\fP
.RS
@@ -1763,15 +1588,40 @@ Show the rollback status.
Query the self test results.
.RE
-
.TP
\fIi2c\fP <\fBi2caddr\fR> <\fBread bytes\fR> [<\fBwrite data\fR>]
.br
This command may be used to execute raw I2C commands with the Master
Write\-Read IPMI command.
+.RE
+.TP
+\fIime\fP
+.RS
+.TP
+\fIhelp\fP
+.br
+
+Print usage information
+.TP
+\fIinfo\fP
+
+Displays information about the Manageability Engine (ME)
+.TP
+\fIupdate\fP <\fBfile\fR>
+.br
+
+Upgrade the ME firmware with the specified image file
+.br
+\fBWARNING\fR You MUST use a supported image provided by your board vendor
+.br
+.TP
+\fIrollback\fP
+
+Perform manual rollback of the ME firmware
.RE
+.RE
.TP
\fIisol\fP
.RS
@@ -1829,7 +1679,6 @@ Special escape sequences are provided to
Note that escapes are only recognized immediately after newline.
.RE
-
.RE
.TP
\fIkontronoem\fP
@@ -1896,209 +1745,572 @@ Set the IP address for this channel.
\fInetmask\fP <\fBx.x.x.x\fR>
.br
-Set the netmask for this channel.
+Set the netmask for this channel.
+.TP
+\fImacaddr\fP <\fBxx:xx:xx:xx:xx:xx\fR>
+.br
+
+Set the MAC address for this channel.
+.TP
+\fIdefgw ipaddr\fP <\fBx.x.x.x\fR>
+.br
+
+Set the default gateway IP address.
+.TP
+\fIdefgw macaddr\fP <\fBxx:xx:xx:xx:xx:xx\fR>
+.br
+
+Set the default gateway MAC address.
+.TP
+\fIbakgw ipaddr\fP <\fBx.x.x.x\fR>
+.br
+
+Set the backup gateway IP address.
+.TP
+\fIbakgw macaddr\fP <\fBxx:xx:xx:xx:xx:xx\fR>
+.br
+
+Set the backup gateway MAC address.
+.TP
+\fIpassword\fP <\fBpass\fR>
+.br
+
+Set the null user password.
+.TP
+\fIsnmp\fP <\fBcommunity string\fR>
+.br
+
+Set the SNMP community string.
+.TP
+\fIuser\fP
+.br
+
+Enable user access mode for userid 1 (issue the `user'
+command to display information about userids for a given channel).
+.TP
+\fIaccess\fP <\fBon|off\fR>
+.br
+
+Set LAN channel access mode.
+.TP
+\fIalert\fP <\fBon|off\fR>
+.br
+
+Enable or disable PEF alerting for this channel.
+.TP
+\fIipsrc\fP <\fBsource\fR>
+.br
+
+Set the IP address source:
+.br
+\fInone\fP unspecified
+.br
+\fIstatic\fP manually configured static IP address
+.br
+\fIdhcp\fP address obtained by BMC running DHCP
+.br
+\fIbios\fP address loaded by BIOS or system software
+.TP
+\fIarp respond\fP <\fBon\fR|\fBoff\fR>
+.br
+
+Set BMC generated ARP responses.
+.TP
+\fIarp generate\fP <\fBon\fR|\fBoff\fR>
+.br
+
+Set BMC generated gratuitous ARPs.
+.TP
+\fIarp interval\fP <\fBseconds\fR>
+.br
+
+Set BMC generated gratuitous ARP interval.
+.TP
+\fIvlan id\fP <\fBoff\fR|\fBid\fR>
+.br
+
+Disable VLAN operation or enable VLAN and set the ID.
+.br
+ID: value of the virtual lan identifier between 1 and 4094 inclusive.
+.TP
+\fIvlan priority\fP <\fBpriority\fR>
+.br
+
+Set the priority associated with VLAN frames.
+.br
+ID: priority of the virtual lan frames between 0 and 7 inclusive.
+.TP
+\fIauth\fP <\fBlevel\fR,\fB...\fR> <\fBtype\fR,\fB...\fR>
+.br
+
+Set the valid authtypes for a given auth level.
+.br
+Levels: callback, user, operator, admin
+.br
+Types: none, md2, md5, password, oem
+.TP
+\fIcipher_privs\fP <\fBprivlist\fR>
+.br
+
+Correlates cipher suite numbers with the maximum privilege
+level that is allowed to use it. In this way, cipher suites can restricted
+to users with a given privilege level, so that, for example,
+administrators are required to use a stronger cipher suite than
+normal users.
+
+The format of \fIprivlist\fR is as follows. Each character represents
+a privilege level and the character position identifies the cipher
+suite number. For example, the first character represents cipher
+suite 0, the second represents cipher suite 1, and so on.
+\fIprivlist\fR must be 15 characters in length.
+
+Characters used in \fIprivlist\fR and their associated privilege levels are:
+
+\fIX\fP Cipher Suite Unused
+.br
+\fIc\fP CALLBACK
+.br
+\fIu\fP USER
+.br
+\fIo\fP OPERATOR
+.br
+\fIa\fP ADMIN
+.br
+\fIO\fP OEM
+.br
+
+So, to set the maximum privilege for cipher suite 0 to USER and suite 1 to
+ADMIN, issue the following command:
+
+> ipmitool \-I \fIinterface\fR lan set \fIchannel\fR cipher_privs uaXXXXXXXXXXXXX
+
+.RE
+.TP
+\fIalert\fP \fIprint\fP [<\fBchannel\fR>] [<\fBalert destination\fR>]
+.br
+
+Print alert information for the specified channel and destination.
+The default will print all alerts for all alert destinations on the
+first found LAN channel.
+
+.TP
+\fIalert\fP \fIset\fP <\fBchannel number\fR> <\fBalert destination\fR> <\fBcommand\fR> <\fBparameter\fR>
+.br
+
+Set an alert on the given LAN channel and destination. Alert Destinations are
+listed via the '\fIlan alert print\fP' command. Valid command/parameter options are:
+.RS
+.TP
+\fIipaddr\fP <\fBx.x.x.x\fR>
+.br
+
+Set alert IP address.
+.TP
+\fImacaddr\fP <\fBxx:xx:xx:xx:xx:xx\fR>
+.br
+
+Set alert MAC address.
+.TP
+\fIgateway\fP <\fBdefault | backup\fR>
+.br
+
+Set the channel gateway to use for alerts.
+.TP
+\fIack\fP <\fBon | off\fR>
+.br
+
+Set Alert Acknowledge on or off.
+.TP
+\fItype\fP <\fBpet | oem1 | oem2\fR>
+.br
+
+Set the destination type as PET or OEM.
+.TP
+\fItime\fP <\fBseconds\fR>
+.br
+
+Set ack timeout or unack retry interval.
+.TP
+\fIretry\fP <\fBnumber\fR>
+.br
+
+Set the number of alert retries.
+.RE
+.TP
+\fIstats\fP \fIget\fP [<\fBchannel number\fR>]
+.br
+
+Retrieve information about the IP connections on the specified channel.
+The default will retrieve statistics on the first found LAN channel.
+.TP
+\fIstats\fP \fIclear\fP [<\fBchannel number\fR>]
+.br
+
+Clear all IP/UDP/RMCP Statistics to 0 on the specified channel.
+The default will clear statistics on the first found LAN channel.
+.RE
+.TP
+\fImc | bmc\fP
+.RS
+.TP
+\fIreset\fP <\fBwarm\fR|\fBcold\fR>
+.br
+
+Instructs the BMC to perform a warm or cold reset.
+.TP
+\fIguid\fP
+
+Display the Management Controller Globally Unique IDentifier.
+.TP
+\fIinfo\fP
+.br
+
+Displays information about the BMC hardware, including device
+revision, firmware revision, IPMI version supported, manufacturer ID,
+and information on additional device support.
+.TP
+\fIwatchdog\fP
+.br
+
+These commands allow a user to view and change the current
+state of the watchdog timer.
+.RS
+.TP
+\fIget\fP
+.br
+
+Show current Watchdog Timer settings and countdown state.
+.TP
+\fIreset\fP
+.br
+
+Reset the Watchdog Timer to its most recent state and restart the
+countdown timer.
+.TP
+\fIoff\fP
+.br
+
+Turn off a currently running Watchdog countdown timer.
+.RE
+.TP
+\fIselftest\fP
+.br
+
+Check on the basic health of the BMC by executing the Get Self Test
+results command and report the results.
+.TP
+\fIgetenables\fP
+.br
+
+Displays a list of the currently enabled options for the BMC.
+.br
+.TP
+\fIsetenables\fP <\fBoption\fR>=[\fIon\fP|\fIoff\fP]
+.br
+
+Enables or disables the given \fIoption\fR. This command is
+only supported over the system interface according to the IPMI
+specification. Currently supported values for \fIoption\fR include:
+.RS
+.TP
+\fIrecv_msg_intr\fP
+.br
+
+Receive Message Queue Interrupt
+.TP
+\fIevent_msg_intr\fP
+.br
+
+Event Message Buffer Full Interrupt
+.TP
+\fIevent_msg\fP
+.br
+
+Event Message Buffer
+.TP
+\fIsystem_event_log\fP
+.br
+
+System Event Logging
+.TP
+\fIoem0\fP
+.br
+
+OEM\-Defined option #0
+.TP
+\fIoem1\fP
+.br
+
+OEM\-Defined option #1
+.TP
+\fIoem2\fP
+.br
+
+OEM\-Defined option #2
+
+.RE
+.TP
+\fIgetsysinfo\fP <\fBargument\fP>
+Retrieves system info from bmc for given argument.
+.br
+See \fIsetsysinfo\fP for argument definitions
+.TP
+\fIsetsysinfo\fP <\fBargument\fP> <\fBstring\fP>
+Stores system info string to bmc for given argument
+.RS
+.TP
+Possible arguments are:
+.RS
+.TP
+\fIprimary_os_name\fP Primary Operating System Name
+.TP
+\fIos_name\fP Operating System Name
+.TP
+\fIsystem_name\fP System Name of Server
+.TP
+\fIdelloem_os_version\fP Running versin of operating system
+.TP
+\fIdelloem_URL\fP URL of BMC Webserver
+.RE
+.RE
+.TP
+\fIchassis\fP
+.RS
+.TP
+\fIstatus\fP
+.br
+
+Displays information regarding the high\-level
+status of the system chassis and main power
+subsystem.
+.TP
+\fIpoh\fP
+.br
+
+This command will return the Power\-On Hours counter.
+.TP
+\fIidentify\fP <\fBinterval\fR>
+
+Control the front panel identify light. Default interval
+is 15 seconds. Use 0 to turn off. Use "force" to turn on
+indefinitely.
+.TP
+\fIrestart_cause\fP
+.br
+
+Query the chassis for the cause of the last system restart.
+.TP
+\fIselftest\fP
+.br
+
+Check on the basic health of the BMC by executing the Get Self Test
+results command and report the results.
+.TP
+\fIpolicy\fP
+.br
+
+Set the chassis power policy in the event power failure.
+.RS
+.TP
+\fIlist\fP
+.br
+
+Return supported policies.
+.TP
+\fIalways\-on\fP
+.br
+
+Turn on when power is restored.
+.TP
+\fIprevious\fP
+.br
+
+Returned to previous state when power is restored.
+.TP
+\fIalways\-off\fP
+.br
+
+Stay off after power is restored.
+.RE
+.TP
+\fIpower\fP
+.br
+
+Performs a chassis control command to view and
+change the power state.
+.RS
.TP
-\fImacaddr\fP <\fBxx:xx:xx:xx:xx:xx\fR>
+\fIstatus\fP
.br
-Set the MAC address for this channel.
+Show current chassis power status.
.TP
-\fIdefgw ipaddr\fP <\fBx.x.x.x\fR>
+\fIon\fP
.br
-Set the default gateway IP address.
+Power up chassis.
.TP
-\fIdefgw macaddr\fP <\fBxx:xx:xx:xx:xx:xx\fR>
+\fIoff\fP
.br
-Set the default gateway MAC address.
+Power down chassis into soft off (S4/S5 state).
+\fBWARNING\fR: This command does not initiate a clean
+shutdown of the operating system prior to powering down the system.
.TP
-\fIbakgw ipaddr\fP <\fBx.x.x.x\fR>
+\fIcycle\fP
.br
-Set the backup gateway IP address.
+Provides a power off interval of at least 1 second. No action
+should occur if chassis power is in S4/S5 state, but it is
+recommended to check power state first and only issue a power
+cycle command if the system power is on or in lower sleep
+state than S4/S5.
.TP
-\fIbakgw macaddr\fP <\fBxx:xx:xx:xx:xx:xx\fR>
+\fIreset\fP
.br
-Set the backup gateway MAC address.
+This command will perform a hard reset.
.TP
-\fIpassword\fP <\fBpass\fR>
+\fIdiag\fP
.br
-Set the null user password.
+Pulse a diagnostic interrupt (NMI) directly to the processor(s).
.TP
-\fIsnmp\fP <\fBcommunity string\fR>
+\fIsoft\fP
.br
-Set the SNMP community string.
+Initiate a soft\-shutdown of OS via ACPI. This can be done in a
+number of ways, commonly by simulating an overtemperture or by
+simulating a power button press. It is necessary for there to
+be Operating System support for ACPI and some sort of daemon
+watching for events for this soft power to work.
+.RE
.TP
-\fIuser\fP
+\fIbootdev\fP <\fBdevice\fR> [<\fIclear\-cmos\fP=\fByes\fR|\fBno\fR>] [<\fIoptions\fP=\fBhelp,...\fR>]
.br
-Enable user access mode for userid 1 (issue the `user'
-command to display information about userids for a given channel).
+Request the system to boot from an alternate boot device on next reboot.
+The \fIclear\-cmos\fP option, if supplied, will instruct the BIOS to
+clear its CMOS on the next reboot. Various options may be used to modify
+the boot device settings. Run \fI"bootdev none options=help"\fP for a list of
+available boot device modifiers/options.
+
+.RS
.TP
-\fIaccess\fP <\fBon|off\fR>
+Currently supported values for <device> are:
+.TP
+\fInone\fP
.br
-Set LAN channel access mode.
+Do not change boot device
.TP
-\fIalert\fP <\fBon|off\fR>
+\fIpxe\fP
.br
-Enable or disable PEF alerting for this channel.
+Force PXE boot
.TP
-\fIipsrc\fP <\fBsource\fR>
+\fIdisk\fP
.br
-Set the IP address source:
-.br
-\fInone\fP unspecified
-.br
-\fIstatic\fP manually configured static IP address
-.br
-\fIdhcp\fP address obtained by BMC running DHCP
-.br
-\fIbios\fP address loaded by BIOS or system software
+Force boot from BIOS default boot device
.TP
-\fIarp respond\fP <\fBon\fR|\fBoff\fR>
+\fIsafe\fP
.br
-Set BMC generated ARP responses.
+Force boot from BIOS default boot device, request Safe Mode
.TP
-\fIarp generate\fP <\fBon\fR|\fBoff\fR>
+\fIdiag\fP
.br
-Set BMC generated gratuitous ARPs.
+Force boot from diagnostic partition
.TP
-\fIarp interval\fP <\fBseconds\fR>
+\fIcdrom\fP
.br
-Set BMC generated gratuitous ARP interval.
+Force boot from CD/DVD
.TP
-\fIvlan id\fP <\fBoff\fR|\fBid\fR>
+\fIbios\fP
.br
-Disable VLAN operation or enable VLAN and set the ID.
-.br
-ID: value of the virtual lan identifier between 1 and 4094 inclusive.
+Force boot into BIOS setup
.TP
-\fIvlan priority\fP <\fBpriority\fR>
+\fIfloppy\fP
.br
-Set the priority associated with VLAN frames.
-.br
-ID: priority of the virtual lan frames between 0 and 7 inclusive.
+Force boot from Floppy/primary removable media
+.RE
.TP
-\fIauth\fP <\fBlevel\fR,\fB...\fR> <\fBtype\fR,\fB...\fR>
+\fIbootparam\fP
.br
-Set the valid authtypes for a given auth level.
-.br
-Levels: callback, user, operator, admin
-.br
-Types: none, md2, md5, password, oem
+Get or set various system boot option parameters.
+.RS
.TP
-\fIcipher_privs\fP <\fBprivlist\fR>
+\fIget\fP <\fBparam #\fR>
.br
-Correlates cipher suite numbers with the maximum privilege
-level that is allowed to use it. In this way, cipher suites can restricted
-to users with a given privilege level, so that, for example,
-administrators are required to use a stronger cipher suite than
-normal users.
+Get boot parameter. Currently supported values for <\fBparam #\fR> are:
-The format of \fIprivlist\fR is as follows. Each character represents
-a privilege level and the character position identifies the cipher
-suite number. For example, the first character represents cipher
-suite 0, the second represents cipher suite 1, and so on.
-\fIprivlist\fR must be 15 characters in length.
+\fI0\fP - Set In Progress
-Characters used in \fIprivlist\fR and their associated privilege levels are:
+\fI1\fP - Service Partition Selector
-\fIX\fP Cipher Suite Unused
-.br
-\fIc\fP CALLBACK
-.br
-\fIu\fP USER
-.br
-\fIo\fP OPERATOR
-.br
-\fIa\fP ADMIN
-.br
-\fIO\fP OEM
-.br
+\fI2\fP - Service Partition Scan
-So, to set the maximum privilege for cipher suite 0 to USER and suite 1 to
-ADMIN, issue the following command:
+\fI3\fP - BMC Boot Flag Valid Bit Clearing
-> ipmitool \-I \fIinterface\fR lan set \fIchannel\fR cipher_privs uaXXXXXXXXXXXXX
+\fI4\fP - Boot Info Acknowledge
-.RE
-.TP
-\fIalert\fP \fIprint\fP [<\fBchannel\fR>] [<\fBalert destination\fR>]
-.br
+\fI5\fP - Boot Flags
-Print alert information for the specified channel and destination.
-The default will print all alerts for all alert destinations on the
-first found LAN channel.
+\fI6\fP - Boot Initiator Info
-.TP
-\fIalert\fP \fIset\fP <\fBchannel number\fR> <\fBalert destination\fR> <\fBcommand\fR> <\fBparameter\fR>
+\fI7\fP - Boot Initiator Mailbox
.br
-Set an alert on the given LAN channel and destination. Alert Destinations are
-listed via the '\fIlan alert print\fP' command. Valid command/parameter options are:
-.RS
.TP
-\fIipaddr\fP <\fBx.x.x.x\fR>
+\fIset\fP <\fBoption\fR> [\fBvalue ...\fR]
.br
-Set alert IP address.
-.TP
-\fImacaddr\fP <\fBxx:xx:xx:xx:xx:xx\fR>
-.br
+Set boot parameter.
-Set alert MAC address.
+.RS
.TP
-\fIgateway\fP <\fBdefault | backup\fR>
+Currently supported values for \fB<option>\fR are:
+.TP
+\fIforce_pxe\fP
.br
-Set the channel gateway to use for alerts.
+Force PXE boot
.TP
-\fIack\fP <\fBon | off\fR>
+\fIforce_disk\fP
.br
-Set Alert Acknowledge on or off.
+Force boot from default hard-drive
.TP
-\fItype\fP <\fBpet | oem1 | oem2\fR>
+\fIforce_safe\fP
.br
-Set the destination type as PET or OEM.
+Force boot from default hard-drive, request Safe Mode
.TP
-\fItime\fP <\fBseconds\fR>
+\fIforce_diag\fP
.br
-Set ack timeout or unack retry interval.
+Force boot from diagnostic partition
.TP
-\fIretry\fP <\fBnumber\fR>
+\fIforce_cdrom\fP
.br
-Set the number of alert retries.
-.RE
-.TP
-\fIstats\fP \fIget\fP [<\fBchannel number\fR>]
+Force boot from CD/DVD
+.TP
+\fIforce_bios\fP
.br
-Retrieve information about the IP connections on the specified channel.
-The default will retrieve statistics on the first found LAN channel.
-.TP
-\fIstats\fP \fIclear\fP [<\fBchannel number\fR>]
-.br
+Force boot into BIOS setup
-Clear all IP/UDP/RMCP Statistics to 0 on the specified channel.
-The default will clear statistics on the first found LAN channel.
+.RE
+.RE
+.RE
.RE
.TP
\fIpef\fP
@@ -2195,9 +2407,7 @@ on the deactivation or activation locked
.TP
\fIportstate\fP \fBset\fR|\fBgetall\fR|\fBgetgranted\fR|\fBgetdenied\fR <\fBparameters\fR>
.br
-
Get or set various port states. See usage for parameter details.
-
.RE
.TP
\fIpower\fP <\fBchassis power command\fR>
@@ -2206,7 +2416,6 @@ Get or set various port states. See usa
Shortcut to the \fIchassis power\fP commands.
See the \fIchassis power\fP commands for usage information.
.RE
-
.TP
\fIraw\fP <\fBnetfn\fR> <\fBcmd\fR> [<\fBdata\fR>]
.br
@@ -2223,8 +2432,7 @@ RAW RSP (5 bytes)
3c 72 0c 00 00
\fBNote\fR that the OpenIPMI driver provided by the Linux kernel will reject the Get Message, Send Message and Read Event Message Buffer commands because it handles the message sequencing internally.
-.br
-
+.RE
.TP
\fIsdr\fP
.RS
@@ -2495,6 +2703,70 @@ Get information about the specified sess
sessions by their id, by their handle number, by their active status,
or by using the keyword `all' to specify all sessions.
.RE
+.TP
+\fIset\fP
+.RS
+.TP
+\fIhostname\fP <\fBhost\fR>
+
+Session hostname.
+.RS
+.RE
+.TP
+\fIusername\fP <\fBuser\fR>
+
+Session username.
+.RS
+.RE
+.TP
+\fIpassword\fP <\fBpass\fR>
+
+Session password.
+.RS
+.RE
+.TP
+\fIprivlvl\fP <\fBlevel\fR>
+
+Session privilege level force.
+.RS
+.RE
+.TP
+\fIauthtype\fP <\fBtype\fR>
+
+Authentication type force.
+.RS
+.RE
+.TP
+\fIlocaladdr\fP <\fBaddr\fR>
+
+Local IPMB address.
+.RS
+.RE
+.TP
+\fItargetaddr\fP <\fBaddr\fR>
+
+Remote target IPMB address.
+.RS
+.RE
+.TP
+\fIport\fP <\fBport\fR>
+
+Remote RMCP port.
+.RS
+.RE
+.TP
+\fIcsv\fP [\fBlevel\fR]
+
+Enable output in comma separated format.
+.RS
+.RE
+.TP
+\fIverbose\fP [\fBverbose\fR]
+
+Verbosity level.
+.RS
+.RE
+.RE
.TP
\fIshell\fP
.RS
diff -up ./lib/ipmi_main.c.manscan ./lib/ipmi_main.c
--- ./lib/ipmi_main.c.manscan 2012-12-03 13:30:06.503601206 +0100
+++ ./lib/ipmi_main.c 2012-12-03 15:20:40.422877937 +0100
@@ -217,43 +217,59 @@ ipmi_option_usage(const char * progname,
{
lprintf(LOG_NOTICE, "%s version %s\n", progname, VERSION);
lprintf(LOG_NOTICE, "usage: %s [options...] <command>\n", progname);
- lprintf(LOG_NOTICE, " -h This help");
- lprintf(LOG_NOTICE, " -V Show version information");
- lprintf(LOG_NOTICE, " -v Verbose (can use multiple times)");
- lprintf(LOG_NOTICE, " -c Display output in comma separated format");
- lprintf(LOG_NOTICE, " -d N Specify a /dev/ipmiN device to use (default=0)");
- lprintf(LOG_NOTICE, " -I intf Interface to use");
- lprintf(LOG_NOTICE, " -H hostname Remote host name for LAN interface");
- lprintf(LOG_NOTICE, " -p port Remote RMCP port [default=623]");
- lprintf(LOG_NOTICE, " -U username Remote session username");
- lprintf(LOG_NOTICE, " -f file Read remote session password from file");
- lprintf(LOG_NOTICE, " -z size Change Size of Communication Channel (OEM)");
- lprintf(LOG_NOTICE, " -S sdr Use local file for remote SDR cache");
-#ifdef ENABLE_ALL_OPTIONS
+
lprintf(LOG_NOTICE, " -a Prompt for remote password");
- lprintf(LOG_NOTICE, " -Y Prompt for the Kg key for IPMIv2 authentication");
- lprintf(LOG_NOTICE, " -e char Set SOL escape character");
+ lprintf(LOG_NOTICE, " -A authtype Force use of auth type NONE, PASSWORD, MD2, MD5 or OEM");
+ lprintf(LOG_NOTICE, " -b channel Set destination channel for bridged request");
+ lprintf(LOG_NOTICE, " -B channel Set transit channel for bridged request (dual bridge)");
+#ifdef ENABLE_ALL_OPTIONS
+* lprintf(LOG_NOTICE, " -c Display output in comma separated format");
+#endif
lprintf(LOG_NOTICE, " -C ciphersuite Cipher suite to be used by lanplus interface");
+#ifdef ENABLE_ALL_OPTIONS
+* lprintf(LOG_NOTICE, " -d N Specify a /dev/ipmiN device to use (default=0)");
+#endif
+ lprintf(LOG_NOTICE, " -e char Set SOL escape character");
+ lprintf(LOG_NOTICE, " -E Read password from IPMI_PASSWORD environment variable");
+#ifdef ENABLE_ALL_OPTIONS
+* lprintf(LOG_NOTICE, " -f file Read remote session password from file");
+#endif
+ lprintf(LOG_NOTICE, " -g Deprecated. Use: -o intelwv2");
+#ifdef ENABLE_ALL_OPTIONS
+* lprintf(LOG_NOTICE, " -h This help");
+* lprintf(LOG_NOTICE, " -H hostname Remote host name for LAN interface");
+#endif
+ lprintf(LOG_NOTICE, " -I intf Interface to use");
lprintf(LOG_NOTICE, " -k key Use Kg key for IPMIv2 authentication");
- lprintf(LOG_NOTICE, " -y hex_key Use hexadecimal-encoded Kg key for IPMIv2 authentication");
+ lprintf(LOG_NOTICE, " -K Read kgkey from IPMI_KGKEY environment variable");
+ lprintf(LOG_NOTICE, " -l lun Set destination lun for raw commands");
lprintf(LOG_NOTICE, " -L level Remote session privilege level [default=ADMINISTRATOR]");
lprintf(LOG_NOTICE, " Append a '+' to use name/privilege lookup in RAKP1");
- lprintf(LOG_NOTICE, " -A authtype Force use of auth type NONE, PASSWORD, MD2, MD5 or OEM");
- lprintf(LOG_NOTICE, " -P password Remote session password");
- lprintf(LOG_NOTICE, " -E Read password from IPMI_PASSWORD environment variable");
- lprintf(LOG_NOTICE, " -K Read kgkey from IPMI_KGKEY environment variable");
lprintf(LOG_NOTICE, " -m address Set local IPMB address");
- lprintf(LOG_NOTICE, " -b channel Set destination channel for bridged request");
- lprintf(LOG_NOTICE, " -t address Bridge request to remote target address");
lprintf(LOG_NOTICE, " -M address Set transit local address for bridge request(dual bridge)");
- lprintf(LOG_NOTICE, " -B channel Set transit channel for bridged request (dual bridge)");
- lprintf(LOG_NOTICE, " -T address Set transit address for bridge request (dual bridge)");
- lprintf(LOG_NOTICE, " -l lun Set destination lun for raw commands");
+ lprintf(LOG_NOTICE, " -N seconds Specify timeout for lan [default=2] / lanplus [default=1] interface");
lprintf(LOG_NOTICE, " -o oemtype Setup for OEM (use 'list' to see available OEM types)");
lprintf(LOG_NOTICE, " -O seloem Use file for OEM SEL event descriptions");
- lprintf(LOG_NOTICE, " -N seconds Specify timeout for lan [default=2] / lanplus [default=1] interface");
+#ifdef ENABLE_ALL_OPTIONS
+* lprintf(LOG_NOTICE, " -p port Remote RMCP port [default=623]");
+#endif
+ lprintf(LOG_NOTICE, " -P password Remote session password");
lprintf(LOG_NOTICE, " -R retry Set the number of retries for lan/lanplus interface [default=4]");
+ lprintf(LOG_NOTICE, " -s Deprecated. Use: -o supermicro");
+#ifdef ENABLE_ALL_OPTIONS
+* lprintf(LOG_NOTICE, " -S sdr Use local file for remote SDR cache");
#endif
+ lprintf(LOG_NOTICE, " -t address Bridge request to remote target address");
+ lprintf(LOG_NOTICE, " -T address Set transit address for bridge request (dual bridge)");
+#ifdef ENABLE_ALL_OPTIONS
+* lprintf(LOG_NOTICE, " -U username Remote session username");
+* lprintf(LOG_NOTICE, " -v Verbose (can use multiple times)");
+* lprintf(LOG_NOTICE, " -V Show version information");
+#endif
+ lprintf(LOG_NOTICE, " -y hex_key Use hexadecimal-encoded Kg key for IPMIv2 authentication");
+ lprintf(LOG_NOTICE, " -Y Prompt for the Kg key for IPMIv2 authentication");
+ lprintf(LOG_NOTICE, " -z size Change Size of Communication Channel (OEM)");
+
lprintf(LOG_NOTICE, "");
ipmi_intf_print(intflist);