kernel-ark/Documentation/virt/kvm/halt-polling.rst
Mauro Carvalho Chehab 2756df60d0 docs: virt: convert halt-polling.txt to ReST format
- Fix document title to match ReST format
- Convert the table to be properly recognized
- Some indentation fixes to match ReST syntax.

Signed-off-by: Mauro Carvalho Chehab <mchehab+huawei@kernel.org>
Reviewed-by: Cornelia Huck <cohuck@redhat.com>
Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>
2020-02-12 20:09:50 +01:00

141 lines
6.6 KiB
ReStructuredText

.. SPDX-License-Identifier: GPL-2.0
===========================
The KVM halt polling system
===========================
The KVM halt polling system provides a feature within KVM whereby the latency
of a guest can, under some circumstances, be reduced by polling in the host
for some time period after the guest has elected to no longer run by cedeing.
That is, when a guest vcpu has ceded, or in the case of powerpc when all of the
vcpus of a single vcore have ceded, the host kernel polls for wakeup conditions
before giving up the cpu to the scheduler in order to let something else run.
Polling provides a latency advantage in cases where the guest can be run again
very quickly by at least saving us a trip through the scheduler, normally on
the order of a few micro-seconds, although performance benefits are workload
dependant. In the event that no wakeup source arrives during the polling
interval or some other task on the runqueue is runnable the scheduler is
invoked. Thus halt polling is especially useful on workloads with very short
wakeup periods where the time spent halt polling is minimised and the time
savings of not invoking the scheduler are distinguishable.
The generic halt polling code is implemented in:
virt/kvm/kvm_main.c: kvm_vcpu_block()
The powerpc kvm-hv specific case is implemented in:
arch/powerpc/kvm/book3s_hv.c: kvmppc_vcore_blocked()
Halt Polling Interval
=====================
The maximum time for which to poll before invoking the scheduler, referred to
as the halt polling interval, is increased and decreased based on the perceived
effectiveness of the polling in an attempt to limit pointless polling.
This value is stored in either the vcpu struct:
kvm_vcpu->halt_poll_ns
or in the case of powerpc kvm-hv, in the vcore struct:
kvmppc_vcore->halt_poll_ns
Thus this is a per vcpu (or vcore) value.
During polling if a wakeup source is received within the halt polling interval,
the interval is left unchanged. In the event that a wakeup source isn't
received during the polling interval (and thus schedule is invoked) there are
two options, either the polling interval and total block time[0] were less than
the global max polling interval (see module params below), or the total block
time was greater than the global max polling interval.
In the event that both the polling interval and total block time were less than
the global max polling interval then the polling interval can be increased in
the hope that next time during the longer polling interval the wake up source
will be received while the host is polling and the latency benefits will be
received. The polling interval is grown in the function grow_halt_poll_ns() and
is multiplied by the module parameters halt_poll_ns_grow and
halt_poll_ns_grow_start.
In the event that the total block time was greater than the global max polling
interval then the host will never poll for long enough (limited by the global
max) to wakeup during the polling interval so it may as well be shrunk in order
to avoid pointless polling. The polling interval is shrunk in the function
shrink_halt_poll_ns() and is divided by the module parameter
halt_poll_ns_shrink, or set to 0 iff halt_poll_ns_shrink == 0.
It is worth noting that this adjustment process attempts to hone in on some
steady state polling interval but will only really do a good job for wakeups
which come at an approximately constant rate, otherwise there will be constant
adjustment of the polling interval.
[0] total block time:
the time between when the halt polling function is
invoked and a wakeup source received (irrespective of
whether the scheduler is invoked within that function).
Module Parameters
=================
The kvm module has 3 tuneable module parameters to adjust the global max
polling interval as well as the rate at which the polling interval is grown and
shrunk. These variables are defined in include/linux/kvm_host.h and as module
parameters in virt/kvm/kvm_main.c, or arch/powerpc/kvm/book3s_hv.c in the
powerpc kvm-hv case.
+-----------------------+---------------------------+-------------------------+
|Module Parameter | Description | Default Value |
+-----------------------+---------------------------+-------------------------+
|halt_poll_ns | The global max polling | KVM_HALT_POLL_NS_DEFAULT|
| | interval which defines | |
| | the ceiling value of the | |
| | polling interval for | (per arch value) |
| | each vcpu. | |
+-----------------------+---------------------------+-------------------------+
|halt_poll_ns_grow | The value by which the | 2 |
| | halt polling interval is | |
| | multiplied in the | |
| | grow_halt_poll_ns() | |
| | function. | |
+-----------------------+---------------------------+-------------------------+
|halt_poll_ns_grow_start| The initial value to grow | 10000 |
| | to from zero in the | |
| | grow_halt_poll_ns() | |
| | function. | |
+-----------------------+---------------------------+-------------------------+
|halt_poll_ns_shrink | The value by which the | 0 |
| | halt polling interval is | |
| | divided in the | |
| | shrink_halt_poll_ns() | |
| | function. | |
+-----------------------+---------------------------+-------------------------+
These module parameters can be set from the debugfs files in:
/sys/module/kvm/parameters/
Note: that these module parameters are system wide values and are not able to
be tuned on a per vm basis.
Further Notes
=============
- Care should be taken when setting the halt_poll_ns module parameter as a large value
has the potential to drive the cpu usage to 100% on a machine which would be almost
entirely idle otherwise. This is because even if a guest has wakeups during which very
little work is done and which are quite far apart, if the period is shorter than the
global max polling interval (halt_poll_ns) then the host will always poll for the
entire block time and thus cpu utilisation will go to 100%.
- Halt polling essentially presents a trade off between power usage and latency and
the module parameters should be used to tune the affinity for this. Idle cpu time is
essentially converted to host kernel time with the aim of decreasing latency when
entering the guest.
- Halt polling will only be conducted by the host when no other tasks are runnable on
that cpu, otherwise the polling will cease immediately and schedule will be invoked to
allow that other task to run. Thus this doesn't allow a guest to denial of service the
cpu.