2005-04-16 22:20:36 +00:00
|
|
|
/*
|
|
|
|
* Copyright 2003 PathScale, Inc.
|
|
|
|
*
|
|
|
|
* Licensed under the GPL
|
|
|
|
*/
|
|
|
|
|
|
|
|
#ifndef __SYSDEP_X86_64_SIGCONTEXT_H
|
|
|
|
#define __SYSDEP_X86_64_SIGCONTEXT_H
|
|
|
|
|
|
|
|
#include <sysdep/sc.h>
|
|
|
|
|
|
|
|
#define IP_RESTART_SYSCALL(ip) ((ip) -= 2)
|
|
|
|
|
|
|
|
#define SC_RESTART_SYSCALL(sc) IP_RESTART_SYSCALL(SC_IP(sc))
|
|
|
|
#define SC_SET_SYSCALL_RETURN(sc, result) SC_RAX(sc) = (result)
|
|
|
|
|
|
|
|
#define SC_FAULT_ADDR(sc) SC_CR2(sc)
|
|
|
|
#define SC_FAULT_TYPE(sc) SC_ERR(sc)
|
|
|
|
|
[PATCH] uml: S390 preparation, abstract host page fault data
This patch removes the arch-specific fault/trap-infos from thread and
skas-regs.
It adds a new struct faultinfo, that is arch-specific defined in
sysdep/faultinfo.h.
The structure is inserted in thread.arch and thread.regs.skas and
thread.regs.tt
Now, segv and other trap-handlers can copy the contents from regs.X.faultinfo
to thread.arch.faultinfo with one simple assignment.
Also, the number of macros necessary is reduced to
FAULT_ADDRESS(struct faultinfo)
extracts the faulting address from faultinfo
FAULT_WRITE(struct faultinfo)
extracts the "is_write" flag
SEGV_IS_FIXABLE(struct faultinfo)
is true for the fixable segvs, i.e. (TRAP == 14)
on i386
UPT_FAULTINFO(regs)
result is (struct faultinfo *) to the faultinfo
in regs->skas.faultinfo
GET_FAULTINFO_FROM_SC(struct faultinfo, struct sigcontext *)
copies the relevant parts of the sigcontext to
struct faultinfo.
On SIGSEGV, call user_signal() instead of handle_segv(), if the architecture
provides the information needed in PTRACE_FAULTINFO, or if PTRACE_FAULTINFO is
missing, because segv-stub will provide the info.
The benefit of the change is, that in case of a non-fixable SIGSEGV, we can
give user processes a SIGSEGV, instead of possibly looping on pagefault
handling.
Since handle_segv() sikked arch_fixup() implicitly by passing ip==0 to segv(),
I changed segv() to call arch_fixup() only, if !is_user.
Signed-off-by: Bodo Stroesser <bstroesser@fujitsu-siemens.com>
Signed-off-by: Jeff Dike <jdike@addtoit.com>
Signed-off-by: Andrew Morton <akpm@osdl.org>
Signed-off-by: Linus Torvalds <torvalds@osdl.org>
2005-05-05 23:15:31 +00:00
|
|
|
#define GET_FAULTINFO_FROM_SC(fi,sc) \
|
|
|
|
{ \
|
|
|
|
(fi).cr2 = SC_CR2(sc); \
|
|
|
|
(fi).error_code = SC_ERR(sc); \
|
|
|
|
(fi).trap_no = SC_TRAPNO(sc); \
|
|
|
|
}
|
2005-04-16 22:20:36 +00:00
|
|
|
|
|
|
|
/* ptrace expects that, at the start of a system call, %eax contains
|
|
|
|
* -ENOSYS, so this makes it so.
|
|
|
|
*/
|
|
|
|
|
|
|
|
#define SC_START_SYSCALL(sc) do SC_RAX(sc) = -ENOSYS; while(0)
|
|
|
|
|
[PATCH] uml: S390 preparation, abstract host page fault data
This patch removes the arch-specific fault/trap-infos from thread and
skas-regs.
It adds a new struct faultinfo, that is arch-specific defined in
sysdep/faultinfo.h.
The structure is inserted in thread.arch and thread.regs.skas and
thread.regs.tt
Now, segv and other trap-handlers can copy the contents from regs.X.faultinfo
to thread.arch.faultinfo with one simple assignment.
Also, the number of macros necessary is reduced to
FAULT_ADDRESS(struct faultinfo)
extracts the faulting address from faultinfo
FAULT_WRITE(struct faultinfo)
extracts the "is_write" flag
SEGV_IS_FIXABLE(struct faultinfo)
is true for the fixable segvs, i.e. (TRAP == 14)
on i386
UPT_FAULTINFO(regs)
result is (struct faultinfo *) to the faultinfo
in regs->skas.faultinfo
GET_FAULTINFO_FROM_SC(struct faultinfo, struct sigcontext *)
copies the relevant parts of the sigcontext to
struct faultinfo.
On SIGSEGV, call user_signal() instead of handle_segv(), if the architecture
provides the information needed in PTRACE_FAULTINFO, or if PTRACE_FAULTINFO is
missing, because segv-stub will provide the info.
The benefit of the change is, that in case of a non-fixable SIGSEGV, we can
give user processes a SIGSEGV, instead of possibly looping on pagefault
handling.
Since handle_segv() sikked arch_fixup() implicitly by passing ip==0 to segv(),
I changed segv() to call arch_fixup() only, if !is_user.
Signed-off-by: Bodo Stroesser <bstroesser@fujitsu-siemens.com>
Signed-off-by: Jeff Dike <jdike@addtoit.com>
Signed-off-by: Andrew Morton <akpm@osdl.org>
Signed-off-by: Linus Torvalds <torvalds@osdl.org>
2005-05-05 23:15:31 +00:00
|
|
|
/* This is Page Fault */
|
|
|
|
#define SEGV_IS_FIXABLE(fi) ((fi)->trap_no == 14)
|
2005-04-16 22:20:36 +00:00
|
|
|
|
|
|
|
extern unsigned long *sc_sigmask(void *sc_ptr);
|
|
|
|
|
|
|
|
#endif
|
|
|
|
|
|
|
|
/*
|
|
|
|
* Overrides for Emacs so that we follow Linus's tabbing style.
|
|
|
|
* Emacs will notice this stuff at the end of the file and automatically
|
|
|
|
* adjust the settings for this buffer only. This must remain at the end
|
|
|
|
* of the file.
|
|
|
|
* ---------------------------------------------------------------------------
|
|
|
|
* Local variables:
|
|
|
|
* c-file-style: "linux"
|
|
|
|
* End:
|
|
|
|
*/
|
|
|
|
|